@@ -0,0 +1,437 @@
|
|
|
+import sys
|
|
|
+import numpy as np
|
|
|
+import pandas as pd
|
|
|
+import string
|
|
|
+import os
|
|
|
+from pandas import Series
|
|
|
+from matplotlib import pyplot as plt
|
|
|
+from pandas.core.frame import DataFrame
|
|
|
+from pandas.core.indexes.base import Index
|
|
|
+from LIB.BACKEND import DBManager
|
|
|
+import datetime
|
|
|
+import time
|
|
|
+import string
|
|
|
+
|
|
|
+
|
|
|
+class SamplingSafty:
|
|
|
+ def __init__(self):
|
|
|
+ pass
|
|
|
+ def main(sn,param,bms_info,df_Diag_Ram_in):
|
|
|
+ df_Diag_Ram_Update_inside=DataFrame(columns=['start_time', 'end_time', 'product_id', 'code', 'level', 'info','advice'])
|
|
|
+ df_Diag_Ram_Update_inside=df_Diag_Ram_Update_inside.append(df_Diag_Ram_in)
|
|
|
+ global QuitErrCount
|
|
|
+ FltInfo=DataFrame(columns=['start_time', 'end_time', 'product_id', 'code', 'level', 'info','advice'])
|
|
|
+ VolStarkCount=[0 for i in range(param.CellVoltNums)]
|
|
|
+ VolCount=[0 for i in range(param.CellVoltNums)]
|
|
|
+ QuitErrCount=[0 for i in range(param.FaultCount)]
|
|
|
+
|
|
|
+ #--------------该电池的所有当前故障-------------
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+ for i in range(0,len(bms_info)):
|
|
|
+ if i==0:
|
|
|
+ bms_infoP=bms_info.loc[i]
|
|
|
+ elif len(bms_info)>=1:
|
|
|
+ bms_infoP=bms_info.loc[i-1]
|
|
|
+ df_Diag_Ram,VolStarkCount,VolCount=SamplingSafty.VoltSamplingDiag(sn,bms_info.loc[i],bms_infoP,param,VolStarkCount,VolCount,df_Diag_Ram_Update_inside)
|
|
|
+ df_Diag_Ram=SamplingSafty.TempSamplingDiag(sn,bms_info.loc[i],bms_infoP,param,df_Diag_Ram)
|
|
|
+ # FltInfo=SamplingSafty.CrntSamplingDiag(sn,bms_info.loc[i],FltInfo,param)
|
|
|
+ return df_Diag_Ram
|
|
|
+
|
|
|
+
|
|
|
+
|
|
|
+ def VoltSamplingDiag(sn,bms_infoN,bms_infoP,param,VolStarkCount,VolCount,df_Diag_Ram):
|
|
|
+ InVMaxBatNo=[]
|
|
|
+ InVMinBatNo=[]
|
|
|
+ StackVolNo=[]
|
|
|
+ OutlierVolNo=[]
|
|
|
+ maxVolt=0
|
|
|
+ minVolt=5
|
|
|
+ ErrorFlg=0
|
|
|
+ TotalVol=0
|
|
|
+ #——————————————————————取最高最低电压————————————————————————————————
|
|
|
+ for t in range(0,param.CellVoltNums):
|
|
|
+ BatNo=['单体电压'+str(t+1)]
|
|
|
+ maxVol=max(maxVolt,float(bms_infoN[BatNo])/1000)
|
|
|
+ if maxVol>maxVolt:
|
|
|
+ MaxBatNo=t+1
|
|
|
+ maxVolt=maxVol
|
|
|
+ if float(bms_infoN[BatNo])/1000>param.CellOVlmt:
|
|
|
+ InVMaxBatNo.append(t+1)
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ minVol=min(minVolt,float(bms_infoN[BatNo])/1000)
|
|
|
+ if minVol<minVolt:
|
|
|
+ MinBatNo=t+1
|
|
|
+ minVolt=minVol
|
|
|
+ if float(bms_infoN[BatNo])/1000<param.CellUVlmt:
|
|
|
+ InVMinBatNo.append(t+1)
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ TotalVol=TotalVol+float(bms_infoN[BatNo]/1000)
|
|
|
+ AvgVol=(TotalVol-maxVol-minVol)/float(param.CellVoltNums-2)
|
|
|
+
|
|
|
+
|
|
|
+ #—————————————————————————————电压无效和断线判断———————————————————————
|
|
|
+ if maxVol>param.CellOVlmt:
|
|
|
+ if minVol<param.CellUVlmt:
|
|
|
+ QuitErrCount[10]=0
|
|
|
+ if not 10 in df_Diag_Ram['code'].values.tolist():#如果故障发生当前故障中没有该故障,则压入该故障
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,10,3,'电池电压采样断线,最高电压为{:.2f}V,电池编号为{},最低电压为{:.2f}V,电池编号为{}'.format(maxVol,MaxBatNo,minVol,MinBatNo),'返厂维修']
|
|
|
+ ErrorFlg=1
|
|
|
+ else:#如果故障发生当前故障中有该故障,则不进行操作
|
|
|
+ pass
|
|
|
+ else:#如果没有故障,并且当前故障表中有该故障,则判断故障是否结束
|
|
|
+ QuitErrCount[50]=0
|
|
|
+ if 10 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[10]=QuitErrCount[10]+1
|
|
|
+ if QuitErrCount[10]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==10].index,['end_time']]=end_time
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ if not 50 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,50,3,str(InVMaxBatNo)+'号电压大于{:.2f}V,采样无效'.format(param.CellOVlmt),'返厂维修']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ elif minVol<param.CellUVlmt:
|
|
|
+ QuitErrCount[50]=0
|
|
|
+ if not 50 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,50,3,str(InVMinBatNo)+'号电压小于{:.2f}V,采样无效'.format(param.CellUVlmt),'返厂维修']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ if 50 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[50]=QuitErrCount[50]+1
|
|
|
+ if QuitErrCount[50]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==50].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ #——————————————————————————————————电压卡滞判断—————————————————————————
|
|
|
+ if ErrorFlg==0:
|
|
|
+ for t in range(0,param.CellVoltNums):
|
|
|
+ BatNo=['单体电压'+str(t+1)]
|
|
|
+ AvgVolGap=abs((float(bms_infoN[BatNo]/1000))-AvgVol)
|
|
|
+ if AvgVolGap>param.AvgVolGap and float(bms_infoN[BatNo]/1000)>param.BLVol and float(bms_infoN[BatNo]/1000)<param.CellFullChrgVolt and not 51 in df_Diag_Ram['code']:
|
|
|
+ if abs(bms_infoN['总电流[A]'])<2:
|
|
|
+ VolCount[t]=VolCount[t]+1
|
|
|
+ else:
|
|
|
+ VolCount[t]=0
|
|
|
+ if VolCount[t]>10:
|
|
|
+ OutlierVolNo.append(t+1)
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ if abs(float(bms_infoN[BatNo])-float(bms_infoP[BatNo]))<=0.0001 and not 52 in df_Diag_Ram['code']:
|
|
|
+ if abs(float(bms_infoN['总电流[A]']))>=10 and not 'PK504' in sn:
|
|
|
+ VolStarkCount[t]=VolStarkCount[t]+1
|
|
|
+ elif abs(float(bms_infoN['总电流[A]']))>=15 and 'PK504' in sn:
|
|
|
+ VolStarkCount[t]=VolStarkCount[t]+1
|
|
|
+ else:
|
|
|
+ VolStarkCount[t]=0
|
|
|
+ if VolStarkCount[t]>10:
|
|
|
+ StackVolNo.append(t+1)
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ if len(OutlierVolNo)>0:
|
|
|
+ QuitErrCount[51]=0
|
|
|
+ if not 51 in df_Diag_Ram['code'].values.tolist():#如果故障发生当前故障中没有该故障,则压入该故障
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,51,2,str(OutlierVolNo)+'号电池电压离群','技术介入诊断']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:#如果故障发生当前故障中有该故障,则不进行操作
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ if 51 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[51]=QuitErrCount[51]+1
|
|
|
+ if QuitErrCount[51]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==51].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ if len(StackVolNo)>0:
|
|
|
+ QuitErrCount[52]=0
|
|
|
+ if not 52 in df_Diag_Ram['code'].values.tolist():#如果故障发生当前故障中没有该故障,则压入该故障
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,52,2,str(StackVolNo)+'号电池电压卡滞','技术介入诊断']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:#如果故障发生当前故障中有该故障,则不进行操作
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ if 51 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[52]=QuitErrCount[52]+1
|
|
|
+ if QuitErrCount[52]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==52].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ return df_Diag_Ram,VolStarkCount,VolCount
|
|
|
+ def TempSamplingDiag(sn,bms_infoN,bms_infoP,param,df_Diag_Ram):
|
|
|
+ #——————————————————————————————————CellTemp————————————————————————————————————
|
|
|
+ InVMaxBatNo=[]
|
|
|
+ InVMinBatNo=[]
|
|
|
+ OutlierTempNo=[]
|
|
|
+ maxCellTempt=-40
|
|
|
+ minCellTempt=55
|
|
|
+ ErrorFlg=0
|
|
|
+ TotalCellTemp=0
|
|
|
+ for t in range(0,param.CellTempNums):
|
|
|
+ BatNo=['单体温度'+str(t+1)]
|
|
|
+ maxCellTemp=max(maxCellTempt,float(bms_infoN[BatNo]))
|
|
|
+ if maxCellTemp>maxCellTempt:
|
|
|
+ MaxBatNo=t+1
|
|
|
+ maxCellTempt=maxCellTemp
|
|
|
+ if float(bms_infoN[BatNo])>param.PackOTlmt:
|
|
|
+ InVMaxBatNo.append(t+1)
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ minCellTemp=min(minCellTempt,float(bms_infoN[BatNo]))
|
|
|
+ if minCellTemp<minCellTempt:
|
|
|
+ MinBatNo=t+1
|
|
|
+ minCellTempt=minCellTemp
|
|
|
+ if float(bms_infoN[BatNo])<param.PackUTlmt:
|
|
|
+ InVMinBatNo.append(t+1)
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ TotalCellTemp=TotalCellTemp+float(bms_infoN[BatNo])
|
|
|
+ if param.CellTempNums>2:
|
|
|
+ AvgCellTemp=(TotalCellTemp-maxCellTemp-minCellTemp)/float(param.CellTempNums-2)
|
|
|
+ else:
|
|
|
+ AvgCellTemp=TotalCellTemp/float(param.CellTempNums)
|
|
|
+#——————————————————————————————————温度无效,离群和断线判断——————————————————————————————————
|
|
|
+ if maxCellTemp>param.PackOTlmt:
|
|
|
+ if minCellTemp<param.PackUTlmt:
|
|
|
+ QuitErrCount[53]=0
|
|
|
+ if not 53 in df_Diag_Ram['code'].values.tolist():#如果故障发生当前故障中没有该故障,则压入该故障
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,53,3,'电池温度采样断线,最高温度为{}℃,电池编号为{},最低温度为{}℃,电池编号为{}'.format(maxCellTemp,MaxBatNo,minCellTemp,MinBatNo),'返厂维修']
|
|
|
+ ErrorFlg=1
|
|
|
+ else:#如果故障发生当前故障中有该故障,则不进行操作
|
|
|
+ pass
|
|
|
+ else:#如果没有故障,并且当前故障表中有该故障,则判断故障是否结束
|
|
|
+ QuitErrCount[2]=0
|
|
|
+ if 53 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[53]=QuitErrCount[53]+1
|
|
|
+ if QuitErrCount[53]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==53].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ if not 2 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,2,3,str(InVMaxBatNo)+'号温度大于{}℃,采样无效'.format(param.PackOTlmt),'返厂维修']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ elif minCellTemp<param.PackUTlmt:
|
|
|
+ QuitErrCount[2]=0
|
|
|
+ if not 2 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,2,3,str(InVMinBatNo)+'号温度小于{}℃,采样无效'.format(param.PackUTlmt),'返厂维修']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ if 2 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[2]=QuitErrCount[2]+1
|
|
|
+ if QuitErrCount[2]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==2].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ if ErrorFlg==0:
|
|
|
+ if param.CellTempNums>2:
|
|
|
+ for t in range(0,param.CellTempNums):
|
|
|
+ BatNo=['单体温度'+str(t+1)]
|
|
|
+ AvgCellTempGap=abs((float(bms_infoN[BatNo]))-AvgCellTemp)
|
|
|
+ if AvgCellTempGap>param.AvgCellTempGap and float(bms_infoN[BatNo])>param.PackUTlmt and float(bms_infoN[BatNo])<param.PackOTlmt and not 8 in df_Diag_Ram['code']:
|
|
|
+ OutlierTempNo.append(t+1)
|
|
|
+ else:
|
|
|
+ AvgCellTempGap=maxCellTemp-minCellTemp
|
|
|
+ if AvgCellTempGap>param.AvgCellTempGap and minCellTemp>param.PackUTlmt and maxCellTemp<param.PackOTlmt and not 8 in df_Diag_Ram['code']:
|
|
|
+ OutlierTempNo=[1,2]
|
|
|
+ if len(OutlierTempNo)>0:
|
|
|
+ QuitErrCount[8]=0
|
|
|
+ if not 8 in df_Diag_Ram['code'].values.tolist():#如果故障发生当前故障中没有该故障,则压入该故障
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,8,2,str(OutlierTempNo)+'号电池异常温度离群','技术介入诊断']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:#如果故障发生当前故障中有该故障,则不进行操作
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ if 8 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[8]=QuitErrCount[8]+1
|
|
|
+ if QuitErrCount[8]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==8].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ #df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['sn']==sn and df_Diag_Ram['code']==8].index,['end_time']]=end_time
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ #——————————————————————————————————OtherTemp————————————————————————————————————
|
|
|
+ InVMaxOtherTempBatNo=[]
|
|
|
+ InVMinOtherTempBatNo=[]
|
|
|
+ OutlierOtherTempNo=[]
|
|
|
+ maxOtherTempt=-40
|
|
|
+ minOtherTempt=91
|
|
|
+ ErrorFlg=0
|
|
|
+ TotalOtherTemp=0
|
|
|
+ if param.OtherTempNums>0:
|
|
|
+ for t in range(0,param.OtherTempNums):
|
|
|
+ BatNo=['其他温度'+str(t+1)]
|
|
|
+ maxOtherTemp=max(maxOtherTempt,float(bms_infoN[BatNo]))
|
|
|
+ if maxOtherTemp>maxOtherTempt:
|
|
|
+ MaxBatNo=t+1
|
|
|
+ maxOtherTempt=maxOtherTemp
|
|
|
+ if float(bms_infoN[BatNo])>param.OtherOTlmt:
|
|
|
+ InVMaxOtherTempBatNo.append(t+1)
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ minOtherTemp=min(minOtherTempt,float(bms_infoN[BatNo]))
|
|
|
+ if minOtherTemp<minOtherTempt:
|
|
|
+ MinBatNo=t+1
|
|
|
+ minOtherTempt=minOtherTemp
|
|
|
+ if float(bms_infoN[BatNo])<param.OtherUTlmt:
|
|
|
+ InVMinOtherTempBatNo.append(t+1)
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ TotalOtherTemp=TotalOtherTemp+float(bms_infoN[BatNo])
|
|
|
+ if param.OtherTempNums>2:
|
|
|
+ AvgOtherTemp=(TotalOtherTemp-maxOtherTemp-minOtherTemp)/float(param.OtherTempNums-2)
|
|
|
+ else:
|
|
|
+ AvgOtherTemp=TotalOtherTemp/float(param.OtherTempNums)
|
|
|
+ #——————————————————————————————————其他温度无效,离群和断线判断——————————————————————————————————
|
|
|
+ if maxOtherTemp>param.OtherOTlmt:
|
|
|
+ if minOtherTemp<param.OtherUTlmt:
|
|
|
+ QuitErrCount[54]=0
|
|
|
+ if not 54 in df_Diag_Ram['code'].values.tolist():#如果故障发生当前故障中没有该故障,则压入该故障
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,54,3,'其他温度采样断线,最高温度为{}℃,传感器编号为{},最低温度为{}℃,传感器编号为{}'.format(maxOtherTemp,MaxBatNo,minOtherTemp,MinBatNo),'返厂维修']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:#如果故障发生当前故障中有该故障,则不进行操作
|
|
|
+ pass
|
|
|
+ else:#如果没有故障,并且当前故障表中有该故障,则判断故障是否结束
|
|
|
+ QuitErrCount[55]=0
|
|
|
+ if 54 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[54]=QuitErrCount[54]+1
|
|
|
+ if QuitErrCount[54]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==54].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ if not 55 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,55,3,str(InVMaxBatNo)+'号传感器温度大于{}℃,采样无效'.format(param.OtherOTlmt),'联系用户核实电池情况,并返厂维修']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ elif minOtherTemp<param.OtherUTlmt:
|
|
|
+ QuitErrCount[55]=0
|
|
|
+ if not 55 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,55,3,str(InVMinBatNo)+'号传感器温度小于{}℃,采样无效'.format(param.OtherUTlmt),'返厂维修']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ if 55 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[55]=QuitErrCount[55]+1
|
|
|
+ if QuitErrCount[55]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==55].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ pass
|
|
|
+ if ErrorFlg==0 and param.OtherTempNums>0:
|
|
|
+ if param.OtherTempNums>2:
|
|
|
+ for t in range(0,param.OtherTempNums):
|
|
|
+ BatNo=['其他温度'+str(t+1)]
|
|
|
+ AvgOtherTempGap=abs((float(bms_infoN[BatNo]))-AvgOtherTemp)
|
|
|
+ if AvgOtherTempGap>param.AvgOtherTempGap and float(bms_infoN[BatNo])>param.OtherUTlmt and float(bms_infoN[BatNo])<param.OtherOTlmt and not 8 in df_Diag_Ram['code']:
|
|
|
+ OutlierTempNo.append(t+1)
|
|
|
+ else:
|
|
|
+ AvgOtherTempGap=maxOtherTemp-minOtherTemp
|
|
|
+ if AvgOtherTempGap>param.AvgOtherTempGap and minOtherTemp>param.OtherUTlmt and maxOtherTemp<param.OtherOTlmt and not 8 in df_Diag_Ram['code']:
|
|
|
+ OutlierTempNo=[1,2]
|
|
|
+ if len(OutlierTempNo)>0:
|
|
|
+ QuitErrCount[56]=0
|
|
|
+ if not 56 in df_Diag_Ram['code'].values.tolist():#如果故障发生当前故障中没有该故障,则压入该故障
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,56,2,str(OutlierTempNo)+'号传感器温度异常离群','技术介入诊断']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:#如果故障发生当前故障中有该故障,则不进行操作
|
|
|
+ pass
|
|
|
+ else:
|
|
|
+ if 56 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[56]=QuitErrCount[56]+1
|
|
|
+ if QuitErrCount[56]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==56].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ if (maxOtherTemp-maxCellTemp)>param.AvgOtherTempGap and maxOtherTemp<param.OtherOTlmt and maxCellTemp<param.PackOTlmt:
|
|
|
+ QuitErrCount[56]=0
|
|
|
+ if not 56 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,56,2,str(OutlierTempNo)+'号传感器温度异常离群','技术立即介入诊断']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:
|
|
|
+ if 56 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[56]=QuitErrCount[56]+1
|
|
|
+ if QuitErrCount[56]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==56].index,['end_time']]=end_time
|
|
|
+
|
|
|
+ if (maxCellTemp-maxOtherTemp)>param.AvgOtherTempGap and maxOtherTemp<param.OtherOTlmt and maxCellTemp<param.PackOTlmt and not 8 in df_Diag_Ram['code']:
|
|
|
+ QuitErrCount[8]=0
|
|
|
+ if not 8 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ df_Diag_Ram.loc[len(df_Diag_Ram)]=[bms_infoN['时间戳'],0,sn,8,2,str(OutlierTempNo)+'号电芯温度异常离群','技术立即介入诊断']
|
|
|
+
|
|
|
+ ErrorFlg=1
|
|
|
+ else:
|
|
|
+ if 8 in df_Diag_Ram['code'].values.tolist():
|
|
|
+ QuitErrCount[8]=QuitErrCount[8]+1
|
|
|
+ if QuitErrCount[8]>6:
|
|
|
+ end_time=datetime.datetime.now()
|
|
|
+ end_time=end_time.strftime('%Y-%m-%d %H:%M:%S')
|
|
|
+ df_Diag_Ram.loc[df_Diag_Ram[df_Diag_Ram['code']==8].index,['end_time']]=end_time
|
|
|
+ return df_Diag_Ram
|
|
|
+
|