123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154 |
- #定义电池参数
- from types import CellType
- import sys
- class BatParam:
- def __init__(self,celltype):
- # if 'PK500' in sn:
- # self.celltype=1 #6040三元电芯
- # elif 'PK502' in sn:
- # self.celltype=2 #4840三元电芯
- # elif 'PK504' in sn:
- # self.celltype=99 #60ah林磷酸铁锂电芯
- # elif 'MGMLXN750' in sn:
- # self.celltype=3 #力信50ah三元电芯
- # elif 'MGMCLN750' in sn:
- # self.celltype=4 #CATL 50ah三元电芯
- # else:
- # print('未找到对应电池编号!!!')
- # sys.exit()
- if celltype==1: #6040
- self.Capacity = 41
- self.PackFullChrgVolt=69.99
- self.CellFullChrgVolt=4.2
- self.CellVoltNums=17
- self.CellTempNums=4
- self.FullChrgSoc=98
- self.PeakSoc=57
- self.PackCrntDec=1
- self.BalCurrent=0.015
- self.LookTab_SOC = [0, 3.5348, 8.3581, 13.181, 18.004, 22.827, 27.651, 32.474, 37.297, 42.120, 46.944, 51.767, 56.590, 61.413, 66.237, 71.060, 75.883, 80.707, 85.530, 90.353, 95.176, 100, 105]
- self.LookTab_OCV = [3.3159, 3.4384, 3.4774, 3.5156, 3.5478, 3.5748, 3.6058, 3.6238, 3.638, 3.6535, 3.6715, 3.6951, 3.7279, 3.7757, 3.8126, 3.8529, 3.8969, 3.9446, 3.9946, 4.0491, 4.109, 4.183, 4.263]
-
- elif celltype==2: #4840
- self.Capacity = 41
- self.PackFullChrgVolt=69.99
- self.CellFullChrgVolt=4.2
- self.CellVoltNums=14
- self.CellTempNums=4
- self.FullChrgSoc=98
- self.PeakSoc=57
- self.PackCrntDec=1
- self.BalCurrent=0.015
- self.LookTab_SOC = [0, 3.5348, 8.3581, 13.181, 18.004, 22.827, 27.651, 32.474, 37.297, 42.120, 46.944, 51.767, 56.590, 61.413, 66.237, 71.060, 75.883, 80.707, 85.530, 90.353, 95.176, 100, 105]
- self.LookTab_OCV = [3.3159, 3.4384, 3.4774, 3.5156, 3.5478, 3.5748, 3.6058, 3.6238, 3.638, 3.6535, 3.6715, 3.6951, 3.7279, 3.7757, 3.8126, 3.8529, 3.8969, 3.9446, 3.9946, 4.0491, 4.109, 4.183, 4.263]
-
- elif celltype==3: #力信50ah三元电芯
- self.Capacity = 51
- self.PackFullChrgVolt=80
- self.CellFullChrgVolt=4.2
- self.CellVoltNums=20
- self.CellTempNums=4
- self.FullChrgSoc=98
- self.PeakSoc=57
- self.PackCrntDec=1
- self.BalCurrent=0.015
- self.LookTab_SOC = [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105]
- self.LookTab_OCV = [3.357, 3.455, 3.493, 3.540, 3.577, 3.605, 3.622, 3.638, 3.655, 3.677, 3.707, 3.757, 3.815, 3.866, 3.920, 3.976, 4.036, 4.099, 4.166, 4.237, 4.325, 4.415]
-
- elif celltype==4: #CATL 50ah三元电芯
- self.Capacity = 50
- self.PackFullChrgVolt=80
- self.CellFullChrgVolt=4.2
- self.CellVoltNums=20
- self.CellTempNums=2
- self.FullChrgSoc=98
- self.PeakSoc=57
- self.PackCrntDec=-1
- self.BalCurrent=0.015
- self.LookTab_SOC = [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105]
- self.LookTab_OCV = [3.152, 3.397, 3.438, 3.481, 3.523, 3.560, 3.586, 3.604, 3.620, 3.638, 3.661, 3.693, 3.748, 3.803, 3.853, 3.903, 3.953, 4.006, 4.063, 4.121, 4.183, 4.253]
-
- elif celltype==99: #60ah磷酸铁锂电芯
- self.Capacity = 54
- self.PackFullChrgVolt=69.99
- self.CellFullChrgVolt=3.5
- self.OcvInflexionBelow=3.285
- self.OcvInflexion2=3.296
- self.OcvInflexion3=3.328
- self.OcvInflexionAbove=3.4
- self.CellVoltNums=20
- self.CellTempNums=4
- self.FullChrgSoc=98
- self.PeakSoc=59
- self.PeakVoltLowLmt=3.35
- self.PeakVoltUpLmt=3.4
- self.PeakCellVolt=[3.362,3.363,3.365,3.366,3.367]
- self.PackCrntDec=1
- self.BalCurrent=0.015
- self.LookTab_SOC = [0.00, 2.40, 6.38, 10.37, 14.35, 18.33, 22.32, 26.30, 30.28, 35.26, 40.24, 45.22, 50.20, 54.19, 58.17, 60.16, 65.14, 70.12, 75.10, 80.08, 84.06, 88.05, 92.03, 96.02, 100.00]
- self.LookTab_OCV = [2.7151, 3.0298, 3.1935, 3.2009, 3.2167, 3.2393, 3.2561, 3.2703, 3.2843, 3.2871, 3.2874, 3.2868, 3.2896, 3.2917, 3.2967, 3.3128, 3.3283, 3.3286, 3.3287, 3.3288, 3.3289, 3.3296, 3.3302, 3.3314, 3.3429]
-
- elif celltype==100: #金茂
- self.Capacity = 228*2
- self.PackFullChrgVolt=3.65*192
- self.CellFullChrgVolt=3.5
- self.OcvInflexionBelow=3.285
- self.OcvInflexion2=3.296
- self.OcvInflexion3=3.328
- self.OcvInflexionAbove=3.4
- self.CellVoltNums=384
- self.CellTempNums=64
- self.FullChrgSoc=98
- self.PeakSoc=59
- self.PeakVoltLowLmt=3.35
- self.PeakVoltUpLmt=3.4
- self.PeakCellVolt=[3.362,3.363,3.365,3.366,3.367]
- self.PackCrntDec=1
- self.BalCurrent=0.015
- self.LookTab_SOC = [0.00, 2.40, 6.38, 10.37, 14.35, 18.33, 22.32, 26.30, 30.28, 35.26, 40.24, 45.22, 50.20, 54.19, 58.17, 60.16, 65.14, 70.12, 75.10, 80.08, 84.06, 88.05, 92.03, 96.02, 100.00]
- self.LookTab_OCV = [2.7151, 3.0298, 3.1935, 3.2009, 3.2167, 3.2393, 3.2561, 3.2703, 3.2843, 3.2871, 3.2874, 3.2868, 3.2896, 3.2917, 3.2967, 3.3128, 3.3283, 3.3286, 3.3287, 3.3288, 3.3289, 3.3296, 3.3302, 3.3314, 3.3429]
-
-
- self.CellOvLv1=3.75
- self.CellOvLv2=3.8
- self.CellUvLv1=2.3
- self.CellUvLv2=2.2
- self.CellVoltDiffLv1=0.6
- self.CellVoltDiffLv2=1
- self.PackVoltOvLv1=self.CellOvLv1*self.CellVoltNums/2
- self.PackVoltOvLv2=self.CellOvLv2*self.CellVoltNums/2
- self.PackVoltUvLv1=self.CellUvLv1*self.CellVoltNums/2
- self.PackVoltUvLv2=self.CellUvLv2*self.CellVoltNums/2
- self.PackChgOc=-800
- self.PackDisOc=800
-
- elif celltype==101: #真芯好电_20ah磷酸铁锂电芯
- self.Capacity = 20
- self.PackFullChrgVolt=54
- self.CellFullChrgVolt=3.65
- self.OcvInflexionBelow=3.2849
- self.OcvInflexion2=3.2998
- self.OcvInflexion3=3.3268
- self.OcvInflexionAbove=3.3333
- self.CellVoltNums=15
- self.CellTempNums=1
- self.FullChrgSoc=100
- self.PeakSoc=62.5
- self.PeakVoltLowLmt=3.35
- self.PeakVoltUpLmt=3.4
- self.PeakCellVolt=[3.362,3.363,3.365,3.366,3.367]
- self.PackCrntDec=1
- self.BalCurrent=0.015
- self.LookTab_SOC = [0.0, 2.5, 5.0, 7.5, 10.0, 12.5, 15.0, 17.5, 20.0, 22.5, 25.0, 27.5, 30.0, 32.5, 35.0, 37.5, 40.0, 42.5, 45.0, 47.5, 50.0, 52.5, 55.0, 57.5, 60.0, 62.5, 65.0, 67.5, 70.0, 72.5, 75.0, 77.5, 80.0, 82.5, 85.0, 87.5, 90.0, 92.5, 95.0, 97.5, 100.0]
- self.LookTab_OCV = [2.5220, 2.8283, 3.0608, 3.1690, 3.1981, 3.2012, 3.2071, 3.2229, 3.2341, 3.2452, 3.2533, 3.2607, 3.2691, 3.2775, 3.2849, 3.2859, 3.2859, 3.2862, 3.2865, 3.2871, 3.2874, 3.2886, 3.2896, 3.2908, 3.2933, 3.2998, 3.3181, 3.3249, 3.3258, 3.3262, 3.3268, 3.3268, 3.3274, 3.3277, 3.3280, 3.3286, 3.3289, 3.3299, 3.3305, 3.3333, 3.4406]
- else:
- print('未找到对应电池编号!!!')
- # sys.exit()
|